Strany 1 - EMTRON DX-3SP

OPERATING MANUAL EMTRON DX-3SP HF LINEAR AMPLIFIER February 2009 Emtron DIVISION OF EMONA ELECTRONICS PTY. LTD. 92-94 Wentworth Avenue, Sydney 201

Strany 2

10 Move the transformer close to the front panel (do not slide it – lift it and move). This will create more space at the back, so that the high vo

Strany 3 - TABLE OF CONTENTS

11 5 FRONT PANEL The following controls and indicators are present on the front panel: 5.1 Controls BAND SWITCH A nine position switch selects

Strany 4

12 ON Air - single LED, green. When pressing PTT, this LED turns on (while in OPERATE and READY). READY - single LED, yellow. Turns on at the end o

Strany 5 - OPERATING MANUAL

13 7 ELECTRICAL CONNECTIONS 7.1 Connections to Transceiver / Exciter Signal connections Before making any connections, ensure that DX-3SP is no

Strany 6 - 1.1 DX-3SP – Internal View

14 PLEASE NOTE: The DX-3SP should not be connected to a mains supply of less than 200VAC! Figure 6 Wiring for 230V shown as example Figure

Strany 7 - 2 TECHNICAL SPECIFICATIONS

15 8 DX-3SP DESCRIPTION 8.1 RF Section The RF section occupies the right hand side of the DX-3SP (looking from the top - front). See picture in

Strany 8

16 8.6 Antenna relay / QSK module The QSK module acts as an antenna relay controlled by the transceiver, via the control board. It switches the an

Strany 9 - 3 UNPACKING

17 9 POWERING UP Before switching the power on, check all the necessary connections: Earth, Antenna, Transceiver, PTT. Make sure the 2 switches on

Strany 10 - 4 INSTALLATION ENVIRONMENT

18 10.1.1 General For each band and operating frequency, the transceiver settings must match the position of the BAND switch on the front panel of

Strany 11 - 5 FRONT PANEL

19 3. During the preliminary tuning, switch PTT on and off several times, to allow time for tube cooling. The tube dissipation (at a given drive le

Strany 12 - 6 REAR PANEL

2 INITIAL SETTINGS FOR PLATE AND LOAD CAPACITORS TEST FREQUENCY BAND FACTORY SETTINGS 50 OHM LOAD USER SETTINGS ANTENNA PLATE LOAD PLATE

Strany 13 - 7 ELECTRICAL CONNECTIONS

20 If there is green Ig2- indication, for a given input drive, try to minimise it and even to obtain red indication. For this, it is likely that LO

Strany 14

21 10.2.3 Hints on good linearity and efficiency Operating with good efficiency: If you are watching the plate current indicator, you must be awar

Strany 15 - 8 DX-3SP DESCRIPTION

22 If it is still not working, unplug the power cord from the mains, then remove the fuses from the fuse holders on the rear panel of DX-3SP and ch

Strany 16 - 8.8 Control board

23 In such a case, it is possible that the high voltage is still shown on the meter, but it does not reach the tube. In any case, this is a major f

Strany 17 - CAPACITORS

24 14 GLOSSARY AC Alternating Current ALC Automatic Level Control AM Amplitude Modulation BALUN Balanced / Unbalanced Transfo

Strany 18 - 10.1.2 Preliminary tuning

25 15 APPENDIX 1: SCHEMATIC DIAGRAMS 15.1 Block Diagrams 15.1.1 DX-3SP Block Diagram BackPanelPrimaryACpowercordLine 130 ampfuseLine 230 ampfuse

Strany 19 - 10.1.3 Final tuning

26 15.1.2 AC INPUT AND WIRING DIAGRAM Figure 8 Note: The 2 Y2 capacitors (4.7nF) are now on the PCB (On Chassis)MT2BlueNeutral/Ground1GBrown200

Strany 20 - 10.2 USING YOUR DX-3SP

27 15.2 Circuit Diagrams 15.2.1 SOFT START Single Phase – Circuit Diagram Figure 9 NEUTRALR1a100/2WC10100nF+C5220uF/25VGATER6270kC112.2nFR113.9k

Strany 21 - 11 SWITCHING THE POWER OFF

28 15.2.2 HIGH VOLTAGE POWER SUPPLY – Circuit Diagram Figure 10

Strany 22 - 12.5 Over-current cut-off

29 15.2.3 RF Module Simplified 1832.2kRS13x150V1FU-728F140VA106330/13W10nF/1kV9-Way123456789A106220k10nF/1kVBIAS2BIAS13k100/13WV2FU-728FEBS(White

Strany 23 - 13 WARRANTY / SERVICE

3 TABLE OF CONTENTS 1 GENERAL DESCRIPTION ...

Strany 24 - 14 GLOSSARY

30 15.2.4 RF output circuit 47pFQSKSw itchingANTENNA 17 301780L2 (Torroid)C150pFRF SENSORSW1-3151500pF80PLATE40 121720 308015250pF303300pF/10kV1

Strany 25 - DX-2sp Block

31 15.2.5 QSK – Circuit Diagram Figure 13 AMPR3100/1WD21N4148+C310uFCOAXIAL CABLE (thick)R1680R22k2RF DECK OUTCOAXIAL CABLE (thin)E M T R O ND3

Strany 26 - Front Panel

32 15.2.6 RF Sensor INC7220pFC110pFREVC510pFDIRC1347pFD1D1N4148C410pFD2D1N4148C640pFR22.2kL2C210pFOUTR322/2WL1C340pFR42.2kC1010nFC1247pFC910nFR

Strany 27 - T R I A C

33 15.2.7 DISPLAY BOARD – Circuit Diagram Figure 15 L63RL16YVR250kVR15kL76RC112.2nFL56YL52YR122k2L38GC61

Strany 28 - Figure 10

34 15.2.8 CONTROL BOARD – Circuit Diagram Figure 16

Strany 29 - CONTROL BOARD

35 15.3 Control Board and Adjustment Points The drawing below shows all the connections to the control board and the adjustment points. Unless you

Strany 30 - 15.2.4 RF output circuit

36 15.3.1 Control Board Component Layout Figure 18 R20 TP4

Strany 31 - E M T R O N

37 15.3.2 Control Board – Solder Side Track work Figure 19

Strany 32 - 15.2.6 RF Sensor

38 16 APPENDIX 2: WAVEFORMS 16.1 QSK Switching Figure 20 No “Hot switching”: The output relay (Top trace) switches first, and then the

Strany 33

39 17 APPENDIX 3: ADJUSTMENTS ADJUSTMENTS TO EMTRON DX-3SP AMPLIFIERS CAUTION Most of the following adjustments require the amplifier to be open

Strany 34 - Figure 16

12 TROUBLESHOOTING - IF SOMETHING GOES WRONG... 21 12.1 NO POWE

Strany 35

40 There are 3 bias adjustment potentiometers: POT3 (BIAS), affecting both tubes and POT10 (BS1) and POT9 (BS2) only adjusting the bias to the tu

Strany 36

41 17.1.4 EBS ADJUSTMENT Adjustment: POT4, marked EBS Usually this adjustment is performed on 20m (14.200 MHz), but it can be done on any band.

Strany 37

42 the EG2 pin on the control board. While operating the amplifier at full power, by rotating the LOAD knob, IG2 can be varied and the screen volta

Strany 38 - 16 APPENDIX 2: WAVEFORMS

43 Figure 22 Control Board – Component side view 17.2 Display Board Adjustments The display board is pre-adjusted during testing. Howeve

Strany 39 - 17 APPENDIX 3: ADJUSTMENTS

44 Adjust potentiometer AMP for correct indication. 17.2.2 PLATE VOLTAGE Adjustment: VR2, marked: VOLT Using a voltmeter with a high voltage prob

Strany 40

45 17.3 RF Sensor (Bridge) Adjustment The amplifier is switched off for this adjustment. Check if adjustment is required as per following proce

Strany 41 - 17.1.4 EBS ADJUSTMENT

46 Emtron DIVISION OF EMONA ELECTRONICS PTY. LTD. 92-94 Wentworth Avenue, Sydney 2010, Australia Tel. +612 921

Strany 42 - 17.1.7 IPTRIP ADJUSTMENT

5 DX-3SP LINEAR AMPLIFIER Serial No ………… OPERATING MANUAL January 2009 CAUTION 1 GENERAL DESCRIPTION The Emtron DX-3SP Linear Amplifier

Strany 43 - 17.2.1 PLATE CURRENT

6 1.1 DX-3SP – Internal View The main components of a DX-3SP amplifier are shown in the picture below. Figure 1 BAND SELECTOR PLA

Strany 44 - 17.2.5 SCREEN CURRENT

7 2 TECHNICAL SPECIFICATIONS FREQUENCY COVERAGE: Complete (manually tuned) coverage of the nine HF amateur bands: 1.800 – 2.000 MHz 3.500 –

Strany 45

8 METERING: The front panel moving LED display systems indicate: “Moving light” LED indicators: • output power • reflected power • screen gri

Strany 46 - Tel. +612 92110988

9 3 UNPACKING The DX-3SP is packed in a heavy duty package easily sufficient to protect the amplifier during transportation, even in case of fair